Owner’s ManualCX 500™LOGIC ASSISTED GATE &EASY RIDER® COMPRESSOR500 SERIES MODULE
Page 10PERIODTwo years from date of purchase.SCOPEAll defects in workmanship and materials. The following are not covered:a. Voltage conversions.b. U
Page 116.2 SERVICE INFORMATIONIf it becomes necessary to return this unit for repair, you must first contact Aphex for a Return Authorization (RMA num
Page 12PO Box 711674 Salt Lake City, Utah 84171 USAPHONE: 801.699.2272 FAX: 435.604.7409www.APHEX.com
Page 2SAFETY DECLARATIONSWARNING: Do not place objects containing liquid on this unit as it is not designed to protect against spillage. Do not expose
Page 3This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These l
Page 4TABLE OF CONTENTS 1.0 INSTALLATION 5 2.0 INTRODUCTION 6 3.0 GATE FUNCTIONS
Page 51. Turn off and unplug your 500 series rack frame. Inspect the card slot you intend to use to make sure that it is clean and free of any debris
Page 62.0 INTRODUCTIONMany other products combine a compressor and gate, but there are problems making them work together. That’s because the com- pre
Page 73.3 HOLDRange: 5mS to 500mS. Balance HOLD with RELEASE to obtain the best gating effect. Usually a longer hold time allows you to use a shorter
Page 84.0 COMPRESSOR FUNCTIONS
Page 94.1 THRESHOLDWhen the input signal level exceeds the thresh- old setting, the compressor engages. Turning the knob counterclockwise lowers the